Domestic Gas Meter



GME G1.6S Gas Meter



The diaphragm meter works on the positive displacement principle wherein the volume received in the inlet side is discharged to the outlet side. Thus making the measurement fully reliable. Further, the diaphragm gas meter works on the differential pressure between inlet and outlet to impulse the diaphragms in the diaphragm boxes. When the gas enters into the meter, it first fills the space inside the inlet meter housing from the rotary valve mouth.



Due to the differential pressure, the gas will alternately enter into the different outlet chamber, alternate charge and discharge will continue till the gas is consumed.  The movement of the rotary valve is transferred to the driving gear via the transmission mechanism and accumulates, the gas volume through the meter to index counter by the ratio calibration gears to realize the metrology of the gas meter. With designing of independent measuring unit structure and high-quality steel case, the product has accuracy and reliability measurement under operating pressure. Designing and producing meticulously, test strictly for GA serials gas meter which suitable for NG, LPG, Town gas, marsh gas measuring.

Features:
  • The outside case made of high-quality steel.
  • Surface spray-paint protects from corrosion.
  • Case closing uses stainless stell for leakage protection.
  • A diaphragm made by advance gluing and vulcanization processes.
  • Use a high-quality bakelite rotary valve.
  • Upper and lower case fixed with glue for leakage protection.
  • Broad metrological performance: G1.6S.
  • High accuracy, long service life with reliability.
  • Lower noise.
  • Equipped with AMR (optional).


Technical characteristics:


Product
Natural gas meter
Type
Diaphragm type ( G1.6S ) for domestic users
Flow
Qmax-2.5m3/hr, Qmin-0.016m3/h
Accuracy
Class 1.5
Rangeability
150:1 or better
Orientation
Left side inlet and right side outlet

Case body
Steel with tamper-proof construction & corrosion resistant powder
coating.
Centre to center distance
110 +/-2mm
Pressure loss
<200Pa
Normal working pressure
0.02bar
Max operating pressure
0.5bar
Cyclic volume
1.2dm3

Error
Qmin≤Q<0.1Qmax
±3%
0.1Qmax≤Q≤Qmax
±1.5%
Min recording reading
0.2dm3
Max recording reading
99999.999m3
Operation temperature
-20+55


Dimensions:


Model
H
W
D
E
A
Weight

G1.6S

220mm

195mm

67mm

165mm

110mm

1.90Kgs